Jump to content

Gabor–Wigner transform

The Gabor transform, named after Dennis Gabor, and the Wigner distribution function, named after Eugene Wigner, are both tools for time-frequency analysis. Since the Gabor transform does not have high clarity, and the Wigner distribution function has a "cross term problem" (i.e. is non-linear), a 2007 study by S. C. Pei and J. J. Ding proposed a new combination of the two transforms that has high clarity and no cross term problem.[1] Since the cross term does not appear in the Gabor transform, the time frequency distribution of the Gabor transform can be used as a filter to filter out the cross term in the output of the Wigner distribution function.

Mathematical definition

[edit]
  • Gabor transform
  • Wigner distribution function
  • Gabor–Wigner transform
There are many different combinations to define the Gabor–Wigner transform. Here four different definitions are given.

Character

[edit]
  1. Cross Term Problem:
    The definition of Wigner distribution function (WDF) is
    is the input signal, the time axis after transform, is the frequency axis after transform.
    If we design our input signal as : , and its WDF presents as below:
    and are called "auto-term", and other components are "cross-term", which is not the correct information from the original signal.
    The Gabor Transform (GT) can avoid the cross-term problem, while the Wigner-distribution function (WDF) has high clarity. By combining the two, the Gabor-Wigner Transform (GWT) achieves both high clarity and the ability to avoid the cross-term problem. Example are shown in the picture below.
    時頻分析2
  2. Rotation relation:
    The GWT has rotation relation with the FRFT, making it useful for filter design, sampling, and multiplexing in the FRFT domain.

Application

[edit]

The Gabor–Wigner transform performs well in image processing, filter design, signal sampling, modulation, demodulation, speech processing, and biomedical engineering.

Filter Design

[edit]

The goal of filter design is to remove unwanted portions of the signal while preserving the necessary parts. By using the Gabor–Wigner transform, we can simultaneously consider filters in both the time domain and frequency domain, representing a form of time-frequency analysis. The main concept is illustrated as follows.

Filter fractional

Signal Modulation

[edit]

The purpose of modulation is to place a signal within a specific time or frequency range. Using the Gabor–Wigner transform, we can simultaneously consider how to introduce more or more suitable signal patterns in both the time and frequency domains. Due to the absence of cross-term issues, it performs better than the Wigner transform.

Mul mod

From the figure (WDF) above, it can also be observed that when using the Wigner transform (WDF), the generated cross-terms have a severe impact on modulation.

Technique for fast implementation of the Gabor-Wigner Transform

[edit]
  1. Due to the lower complexity of the Gabor transform compared to the Wigner transform, the Gabor transform is usually prioritized for calculation. When calculating the Wigner transform, it is only necessary to compute the Gabor transform in non-zero regions, as the values in other regions approach zero. Mathematically, this can be expressed as
  2. When is a real function, for the Gabor transform, . This allows for a significant reduction in the required memory area when designing memory.

Comparison

[edit]
Time-frequency analysis Advantages Disadvantages Complexity
Gabor transform without cross-term lower clarity Low
Wigner-distribution function higher clarity with cross-term Medium
Gabor–Wigner transform high clarity and without cross-term high computational load High

See also

[edit]

References

[edit]
  1. ^ S. C. Pei and J. J. Ding, “Relations between Gabor transforms and fractional Fourier transforms and their applications for signal processing,” IEEE Trans. Signal Process., vol. 55, no. 10, pp. 4839–4850, Oct. 2007.
Arc.Ask3.Ru: конец переведенного документа.
Arc.Ask3.Ru
Номер скриншота №: 3ce9f8ac8cb9d40c68d636d7dbd7a39f__1709113380
URL1:https://arc.ask3.ru/arc/aa/3c/9f/3ce9f8ac8cb9d40c68d636d7dbd7a39f.html
Заголовок, (Title) документа по адресу, URL1:
Gabor–Wigner transform - Wikipedia
Данный printscreen веб страницы (снимок веб страницы, скриншот веб страницы), визуально-программная копия документа расположенного по адресу URL1 и сохраненная в файл, имеет: квалифицированную, усовершенствованную (подтверждены: метки времени, валидность сертификата), открепленную ЭЦП (приложена к данному файлу), что может быть использовано для подтверждения содержания и факта существования документа в этот момент времени. Права на данный скриншот принадлежат администрации Ask3.ru, использование в качестве доказательства только с письменного разрешения правообладателя скриншота. Администрация Ask3.ru не несет ответственности за информацию размещенную на данном скриншоте. Права на прочие зарегистрированные элементы любого права, изображенные на снимках принадлежат их владельцам. Качество перевода предоставляется как есть. Любые претензии, иски не могут быть предъявлены. Если вы не согласны с любым пунктом перечисленным выше, вы не можете использовать данный сайт и информация размещенную на нем (сайте/странице), немедленно покиньте данный сайт. В случае нарушения любого пункта перечисленного выше, штраф 55! (Пятьдесят пять факториал, Денежную единицу (имеющую самостоятельную стоимость) можете выбрать самостоятельно, выплаичвается товарами в течение 7 дней с момента нарушения.)